T I M S


TIMS can accurately measure and store data from
the K thermocouple port (10channels), the analog port (8 channels),
and the digital input port (4channels).

For remote monitoring of devices and systems, data can be
transferred through various communication lines at low cost.

TIMS can measure temperatures from -200 to 1200ºC with
a resolution of 0.1ºC. And it can log a maximum of 23000 times
the amount of data
in its internal memory. Logging pace can be
freely set from a minimum of 1 second to
a maximum of 3600 seconds.

A logging pace of 60 seconds will result in more than 6 months of data.




Specifications
System Outline





Input

Item Specifications and recommended operating conditions
Analog voltage 0 to +5V, 5mV resolution, 8ch
Digital input contact point input, open collector input, 4ch
Digital output LED lighting or equal load, 4ch
Temperature measurement, K thermocouple 0 to 100% RH (option)
Working temperature range -30 to 80ºC
Working humidity limit up to 90%RH (option)


Interface

Item Specifications
Standard RS232C, RS485 (for expansion up to a maximum of 100 units)
Baud rate 115200, 57600, 38400, 19200, 9600, 4800, 2400bps
Method pace synchronous transmission


Function

Item Specifications and recommended operating conditions
Power supply
AC adapter Input voltage 100V
DC Input 8V to 16V
Built-in NiMH battery 4.8V 1200mAh
Size 100mm(W) × 35mm(H) ×126mm(D)
Weight 550g, including battery

*The TIMS system will be released next year.